<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Mouse Catheters &#8211; SAI Infusion Technologies</title>
	<atom:link href="https://www.sai-infusion.com/product-category/mouse-catheters/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.sai-infusion.com</link>
	<description>Infusion and Sampling Products for Laboratory Animal Research</description>
	<lastBuildDate>Thu, 18 Jun 2026 19:20:31 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.0</generator>

<image>
	<url>https://www.sai-infusion.com/wp-content/uploads/2024/12/favicon_512-66x66.png</url>
	<title>Mouse Catheters &#8211; SAI Infusion Technologies</title>
	<link>https://www.sai-infusion.com</link>
	<width>32</width>
	<height>32</height>
</image> 
<site xmlns="com-wordpress:feed-additions:1">244557463</site>	<item>
		<title>Mouse Tracheal catheter</title>
		<link>https://www.sai-infusion.com/product/mouse-intra-tracheal-catheter/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Thu, 30 Jan 2025 16:17:51 +0000</pubDate>
				<guid isPermaLink="false">https://project2.digitalendeavordev.com/?post_type=product&#038;p=5883</guid>

					<description><![CDATA[These tracheal catheters may be used for ventilation, sampling, or administration. Three standard sizes are available for use in mice, rats, and other small rodents. Our tracheal tubes may be trimmed to the appropriate size if necessary. Come with a flexible cannula and y-adaptor for minimum dead space Readily connect to anesthesia systems Part # Gauge Tip  [...]]]></description>
										<content:encoded><![CDATA[<p>These tracheal catheters may be used for ventilation, sampling, or administration. Three standard sizes are available for use in mice, rats, and other small rodents. Our tracheal tubes may be trimmed to the appropriate size if necessary.</p>
<ul>
<li>Come with a flexible cannula and y-adaptor for minimum dead space</li>
<li>Readily connect to anesthesia systems</li>
</ul>
<div style="height: 20px; width: 100%;"></div>
<div class="table-2">
<table width="100%">
<thead>
<tr>
<th>Part #</th>
<th>Gauge</th>
<th>Tip Length</th>
</tr>
</thead>
<tbody>
<tr>
<td>TRA-03</td>
<td>24</td>
<td>0.5</td>
</tr>
</tbody>
</table>
</div>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">5883</post-id>	</item>
		<item>
		<title>Mouse Tail Cuff Catheter</title>
		<link>https://www.sai-infusion.com/product/mouse-femoral-vein-catheter-fvc-for-tail-cuff/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Thu, 30 Jan 2025 16:01:17 +0000</pubDate>
				<guid isPermaLink="false">https://project2.digitalendeavordev.com/?post_type=product&#038;p=5357</guid>

					<description><![CDATA[These Rounded Tip Mouse Femoral Vein Catheters for Tail Cuff are made with Polyurethane to increase patency and reduce vessel trauma. Tapered catheters are also available. Ask us if you need custom tubing, fittings, or lengths. Biocompatible with low vessel trauma and increased patency Custom lengths and suture bead placement available, contact us with questions Part #  [...]]]></description>
										<content:encoded><![CDATA[<p>These Rounded Tip Mouse Femoral Vein Catheters for Tail Cuff are made with Polyurethane to increase patency and reduce vessel trauma. Tapered catheters are also available. Ask us if you need custom tubing, fittings, or lengths.</p>
<ul>
<li>Biocompatible with low vessel trauma and increased patency</li>
<li>Custom lengths and suture bead placement available, contact us with questions</li>
</ul>
<div style="height: 20px; width: 100%;"></div>
<div class="table-2">
<table width="100%">
<thead>
<tr>
<th>Part #</th>
<th>Tip Length</th>
<th>Tip O.D.</th>
<th>Total Length</th>
<th>Needle Gauge</th>
<th>Material</th>
<th>Suture Beads</th>
</tr>
</thead>
<tbody>
<tr>
<td>MTC-02</td>
<td>12 mm</td>
<td>1 F</td>
<td>54 cm</td>
<td>25</td>
<td>Polyurethane</td>
<td>2</td>
</tr>
</tbody>
</table>
</div>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">5357</post-id>	</item>
		<item>
		<title>Mouse Jugular Catheter</title>
		<link>https://www.sai-infusion.com/product/mouse-jugular-vein-catheters-jvc/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Thu, 30 Jan 2025 16:00:46 +0000</pubDate>
				<guid isPermaLink="false">https://project2.digitalendeavordev.com/?post_type=product&#038;p=5327</guid>

					<description><![CDATA[Our biocompatible polyurethane and silicone catheters are designed to enhance patency and minimize vessel trauma during implantation. All these catheters have beads accurately positioned from the catheter tip for optimal implantation position within the vessel. Beads are also positioned to provide a secure tension loop to maximize continued patency during movement and growth. If you  [...]]]></description>
										<content:encoded><![CDATA[<p>Our biocompatible polyurethane and silicone catheters are designed to enhance patency and minimize vessel trauma during implantation. All these catheters have beads accurately positioned from the catheter tip for optimal implantation position within the vessel. Beads are also positioned to provide a secure tension loop to maximize continued patency during movement and growth. If you have any questions, please contact us.</p>
<ul>
<li>Made from silicone or polyurethane</li>
<li>Available in 12cm and 14cm lengths</li>
<li>Designed to enhance patency</li>
</ul>
<div style="height: 20px; width: 100%;"></div>
<div class="table-2">
<table width="100%">
<thead>
<tr>
<th>Part #</th>
<th><strong>Animal Size</strong></th>
<th>Tip Length</th>
<th>Tip O.D.</th>
<th><strong>Total Length</strong></th>
<th>Needle Gauge</th>
<th>Material</th>
<th>Suture Beads</th>
</tr>
</thead>
<tbody>
<tr>
<td>MJC-01</td>
<td>&lt; 25 g</td>
<td>9 mm</td>
<td>1 F</td>
<td>14 cm</td>
<td>25</td>
<td>Polyurethane</td>
<td>2</td>
</tr>
<tr>
<td>MJC-01B</td>
<td>&gt; 25 g</td>
<td>10 mm</td>
<td>1 F</td>
<td>19 cm</td>
<td>23</td>
<td>Polyurethane</td>
<td>2</td>
</tr>
<tr>
<td>MJC-02</td>
<td>25-30 g</td>
<td>11 mm</td>
<td>1 F</td>
<td>14 cm</td>
<td>25</td>
<td>Polyurethane</td>
<td>2</td>
</tr>
<tr>
<td>MJC-03</td>
<td>&gt; 30 g</td>
<td>13 mm</td>
<td>1 F</td>
<td>14 cm</td>
<td>25</td>
<td>Polyurethane</td>
<td>2</td>
</tr>
<tr>
<td>MJC-04</td>
<td>&gt; 25 g</td>
<td>10 mm</td>
<td>1 F</td>
<td>34 cm</td>
<td>25</td>
<td>Polyurethane</td>
<td>2</td>
</tr>
<tr>
<td>MJC-05</td>
<td>&gt; 25 g</td>
<td>11 mm</td>
<td>2.5 F</td>
<td>12 cm</td>
<td>23</td>
<td>Silicone</td>
<td>2</td>
</tr>
<tr>
<td>MJCR-03</td>
<td>&gt;30 g</td>
<td>11 mm</td>
<td>2 F <span style="color: #0000ff;">ROUNDED</span></td>
<td></td>
<td>23</td>
<td>Polyurethane</td>
<td>2</td>
</tr>
<tr>
<td>MACR-01</td>
<td>&gt;30 g</td>
<td>10 mm</td>
<td>2 F <span style="color: #0000ff;">ROUNDED</span></td>
<td>10 cm</td>
<td>25</td>
<td>polyurethane</td>
<td>1</td>
</tr>
</tbody>
</table>
</div>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">5327</post-id>	</item>
		<item>
		<title>32G Adjustable Mouse Intrathecal Catheter</title>
		<link>https://www.sai-infusion.com/product/mouse-intrathecal-catheters/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Thu, 30 Jan 2025 16:00:23 +0000</pubDate>
				<guid isPermaLink="false">https://project2.digitalendeavordev.com/?post_type=product&#038;p=5315</guid>

					<description><![CDATA[Catheters for intrathecal (IT) delivery or sampling in mice. SAI offers a range of catheters and cannula for the collection of CSF and for the administration of compounds to the intrathecal space in mice, rats, canines, primates and sheep . Draw cerebrospinal fluid, or perform intrathecal infusion in the subarachnoid space with these reinforced catheters. PTFE coated stylet  [...]]]></description>
										<content:encoded><![CDATA[<p>Catheters for intrathecal (IT) delivery or sampling in mice. SAI offers a range of catheters and cannula for the collection of CSF and for the administration of compounds to the intrathecal space in mice, rats, canines, primates and sheep . Draw cerebrospinal fluid, or perform intrathecal infusion in the subarachnoid space with these reinforced catheters.</p>
<ul>
<li>PTFE coated stylet slides smoothly out of catheter</li>
<li>Reinforced tubing junction minimizes kinking at exit point from intrathecal space</li>
<li>All catheters are supplied sterile (ETO exposed)</li>
</ul>
<div style="height: 20px; width: 100%;"></div>
<div class="table-2">
<table width="100%">
<thead>
<tr>
<th>Part #</th>
<th>Description</th>
</tr>
</thead>
<tbody>
<tr>
<td>MIT-01</td>
<td>Mouse intrathecal polyurethane catheter 32G tip, 5.5 cm long, 22G connection</td>
</tr>
<tr>
<td>MIT-02</td>
<td>Mouse intrathecal polyurethane catheter 32G tip, 6 cm long, 22G connection</td>
</tr>
</tbody>
</table>
</div>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">5315</post-id>	</item>
		<item>
		<title>Polyurethane Mouse Femoral Vein Catheter</title>
		<link>https://www.sai-infusion.com/product/mouse-femoral-vein-fvc-catheters/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Thu, 30 Jan 2025 15:59:42 +0000</pubDate>
				<guid isPermaLink="false">https://project2.digitalendeavordev.com/?post_type=product&#038;p=5309</guid>

					<description><![CDATA[SAI's Mouse Femoral Vein Catheters are made with Polyurethane to increase patency and to reduce vessel trauma. Femoral vein catheters for tail cuff are also available. Ask us if you need custom tubing, fittings, or lengths. Biocompatible, with low vessel trauma and increased patency Lengths listed are 17cm and 50cm with two suture beads Custom lengths  [...]]]></description>
										<content:encoded><![CDATA[<p>SAI&#8217;s Mouse Femoral Vein Catheters <span class="product_detail">are made with Polyurethane to increase patency and to reduce vessel trauma. Femoral vein catheters for tail cuff are also available. Ask us if you need custom tubing, fittings, or lengths.</span></p>
<ul>
<li>Biocompatible, with low vessel trauma and increased patency</li>
<li>Lengths listed are 17cm and 50cm with two suture beads</li>
<li>Custom lengths and suture bead placement available, contact us with questions.</li>
</ul>
<div style="height: 20px; width: 100%;"></div>
<div class="table-2">
<table width="100%">
<thead>
<tr>
<th>Part #</th>
<th>Animal Size</th>
<th>Tip Length</th>
<th>Tip O.D.</th>
<th>Total Length</th>
<th>Needle Gauge</th>
<th>Material</th>
<th>Suture Beads</th>
</tr>
</thead>
<tbody>
<tr>
<td>MFV-01</td>
<td>&gt; 25 g</td>
<td>10 mm</td>
<td>1 F</td>
<td>50 cm</td>
<td>25</td>
<td>Polyurethane</td>
<td>2</td>
</tr>
<tr>
<td>MFV-02</td>
<td>&lt; 25 g</td>
<td>10 mm</td>
<td>1 F</td>
<td>17 cm</td>
<td>25</td>
<td>Polyurethane</td>
<td>2</td>
</tr>
</tbody>
</table>
</div>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">5309</post-id>	</item>
		<item>
		<title>Mouse PE CSF Collection Line with 30G Hub</title>
		<link>https://www.sai-infusion.com/product/rodent-csf-collection-catheters/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Thu, 30 Jan 2025 15:57:53 +0000</pubDate>
				<guid isPermaLink="false">https://project2.digitalendeavordev.com/?post_type=product&#038;p=5299</guid>

					<description><![CDATA[Collect clean CSF directly from the rodent Cisterna Magna. 15" of PE tubing allows for collection of up to 70ul CSF.  Pool CSF from multiple mice, or collect from a single rat.  The clear PE line allows for visualization of the CSF during collection.  Immediately identify any blood contamination and discard only the contaminated CSF.  SAI offers  [...]]]></description>
										<content:encoded><![CDATA[<p>Collect clean CSF directly from the rodent Cisterna Magna. 15&#8243; of PE tubing allows for collection of up to 70ul CSF.  Pool CSF from multiple mice, or collect from a single rat.  The clear PE line allows for visualization of the CSF during collection.  Immediately identify any blood contamination and discard only the contaminated CSF.  SAI offers a range of catheters and cannula for the collection of CSF and for the administration of compounds to the intrathecal space in mice, rats, canines, primates and sheep . Draw cerebrospinal fluid, or perform intrathecal infusion in the subarachnoid space with these reinforced catheters.</p>
<ul>
<li>30G needle allows access to the smallest spaces with minimal damage</li>
<li>15&#8243; PE tubing for 70ul of collected CSF</li>
<li>Textured hub for improved needle manipulation</li>
<li>All catheters are supplied sterile (ETO exposed)</li>
</ul>
<div style="height: 20px; width: 100%;"></div>
<div class="table-2">
<table width="100%">
<thead>
<tr>
<th>Part #</th>
<th>Description</th>
</tr>
</thead>
<tbody>
<tr>
<td>MCSF-02</td>
<td>Rodent CSF collection catheter &#8211; 30G needle, 15&#8243; long tubing, with luer connection for syringe access</td>
</tr>
</tbody>
</table>
</div>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">5299</post-id>	</item>
		<item>
		<title>Micro Cannulation System</title>
		<link>https://www.sai-infusion.com/product/micro-cannula/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Thu, 30 Jan 2025 15:57:14 +0000</pubDate>
				<guid isPermaLink="false">https://project2.digitalendeavordev.com/?post_type=product&#038;p=5294</guid>

					<description><![CDATA[Our Micro-Cannula simplifies vascular access for small vessels in rodents and other small species. This cannula features a sharp stylet to aid insertion and a tapered tip to make catheter placement fast and reliable. This catheter is ideal for acute injections into small vessels, however, for tail veins, we suggest our tail vein catheters or butterfly catheters.  [...]]]></description>
										<content:encoded><![CDATA[<p>Our Micro-Cannula simplifies vascular access for small vessels in rodents and other small species. This cannula features a sharp stylet to aid insertion and a tapered tip to make catheter placement fast and reliable. This catheter is ideal for acute injections into small vessels, however, for tail veins, we suggest our tail vein catheters or butterfly catheters. Please use the Order Form to complete a purchase, or contact us with questions.</p>
<ul>
<li>Standard female luer fitting makes fluid connections quick and simple</li>
<li>PTFE tubing is biocompatible and resistant to organic vehicles</li>
<li>Removable stylet aids in insertion</li>
<li>Retention bead at 1cm from the tip</li>
<li>Can be modified to include additional suture beads (additional charges apply)</li>
<li>Connects to standard syringes or any other luer fitting.</li>
</ul>
<div style="height: 20px; width: 100%;"></div>
<div class="table-2">
<table width="100%">
<thead>
<tr>
<th>Part #</th>
<th>Description</th>
</tr>
</thead>
<tbody>
<tr>
<td>MC-27</td>
<td>0.016&#8243; OD x 0.008&#8243; ID (0.2mm ID x 0.4mm OD) Tip with Sharpened Stylet and Female luer, total length 8 cm</td>
</tr>
<tr>
<td>MC-28</td>
<td>0.016&#8243; OD x 0.008&#8243; ID (0.2mm ID x 0.4mm OD) Tip with Sharpened Stylet and Female luer, total length 10 cm</td>
</tr>
</tbody>
</table>
</div>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">5294</post-id>	</item>
		<item>
		<title>Mouse Arterial Catheters without Stylet</title>
		<link>https://www.sai-infusion.com/product/mouse-arterial-catheters-cac/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Thu, 30 Jan 2025 15:57:13 +0000</pubDate>
				<guid isPermaLink="false">https://project2.digitalendeavordev.com/?post_type=product&#038;p=5290</guid>

					<description><![CDATA[Our biocompatible catheters for the carotid artery of the mouse are designed for accurate placement to maximize patency. They are sized to fit into small mouse vessels, with suture beads located for optimal positioning. These catheters may be used for blood pressure measurement or infusion. A complete list of our mouse catheters can be found here.  [...]]]></description>
										<content:encoded><![CDATA[<p>Our biocompatible catheters for the carotid artery of the mouse are designed for accurate placement to maximize patency. They are sized to fit into small mouse vessels, with suture beads located for optimal positioning. These catheters may be used for blood pressure measurement or infusion. A complete list of our mouse catheters can be found here.</p>
<ul>
<li>Made from polyurethane</li>
<li>Accurately positioned beads for optimal implantation within the vessel and to maximize patency during growth and movement</li>
<li>Used for blood pressure measurement or infusion</li>
</ul>
<div style="height: 20px; width: 100%;"></div>
<div class="table-2">
<table width="100%">
<thead>
<tr>
<th>Part #</th>
<th>Animal Size</th>
<th>Tip Length</th>
<th>Tip O.D.</th>
<th>Total Length</th>
<th>Needle Gauge</th>
<th>Material</th>
<th>Suture Beads</th>
</tr>
</thead>
<tbody>
<tr>
<td>MAC-01</td>
<td>&lt; 25 g</td>
<td>9 mm</td>
<td>1 F</td>
<td>14 cm</td>
<td>25</td>
<td>Polyurethane</td>
<td>2</td>
</tr>
<tr>
<td>MAC-02</td>
<td>&gt; 25 g</td>
<td>10 mm</td>
<td>1 F</td>
<td>50 cm</td>
<td>25</td>
<td>Polyurethane</td>
<td>2</td>
</tr>
<tr>
<td>MAC-2B</td>
<td>&gt; 25 g</td>
<td>10 mm</td>
<td>1 F</td>
<td>15 cm</td>
<td>25</td>
<td>Polyurethane</td>
<td>2</td>
</tr>
<tr>
<td>MAC-05</td>
<td>&gt; 25 g</td>
<td>30 mm</td>
<td>1 F</td>
<td>15 cm</td>
<td>25</td>
<td>Polyurethane</td>
<td>3</td>
</tr>
</tbody>
</table>
</div>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">5290</post-id>	</item>
		<item>
		<title>Lab Animal Winged Infusion Sets</title>
		<link>https://www.sai-infusion.com/product/butterfly-needles/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Thu, 30 Jan 2025 15:41:10 +0000</pubDate>
				<guid isPermaLink="false">https://project2.digitalendeavordev.com/?post_type=product&#038;p=4871</guid>

					<description><![CDATA[These specialty needles (often called Winged Infusion Sets) offer a highly effective means of accessing a peripheral blood vessel for infusion or sampling in small and large animals. When compared to traditional straight needles, butterfly needles are often shorter, include wings on both sides of the needle for stability and have tubing attached to the end  [...]]]></description>
										<content:encoded><![CDATA[<p>These specialty needles (often called Winged Infusion Sets) offer a highly effective means of accessing a peripheral blood vessel for infusion or sampling in small and large animals. When compared to traditional straight needles, butterfly needles are often shorter, include wings on both sides of the needle for stability and have tubing attached to the end for easy connection to syringes or collection devices. Make small blood collection even easier with our large selection of blood collection vials.</p>
<ul>
<li>Wings provide added grip and accuracy when handling the needle</li>
<li>Wide variety of needle sizes and tubing lengths and can be customized</li>
<li>Often used for rodent tail vein infusion or in the cepahalic or saphenous veins in larger species</li>
<li>Biocompatible and resistant to organic vehicles</li>
<li>Connect to standard syringes or any other luered fitting</li>
</ul>
<div style="height: 20px; width: 100%;"></div>
<div class="table-2">
<table width="100%">
<thead>
<tr>
<th>Part #</th>
<th>Needle</th>
<th>Tubing</th>
<th>Connector</th>
<th>Unit</th>
</tr>
</thead>
<tbody>
<tr>
<td>BFL-23-11.5</td>
<td>23G 3/4&#8243; Butterfly</td>
<td>11.5&#8243; Non-DEHP PVC Extension (150ul dead vol)</td>
<td>Female luer</td>
<td>50/box</td>
</tr>
<tr>
<td>BFL-25-11.5</td>
<td>25G 3/4&#8243; Butterfly</td>
<td>11.5&#8243; Non-DEHP PVC Extension (150ul dead vol)</td>
<td>Female luer</td>
<td>50/box</td>
</tr>
<tr>
<td>BFL-24</td>
<td>27G 1/2&#8243; Butterfly</td>
<td>24cm polyurethane tubing (ID: 0.013”)</td>
<td>Accepts 27G blunt needle</td>
<td>Each</td>
</tr>
<tr>
<td>BF-27-01</td>
<td>27G 1/2&#8243; Butterfly</td>
<td>12cm polyurethane tubing (ID: 0.013”)</td>
<td>Accepts 27G blunt needle</td>
<td>Each</td>
</tr>
<tr>
<td>BF-27-13</td>
<td>27G 1/2&#8243; Butterfly</td>
<td>5cm polyurethane tubing (ID: 0.013”)</td>
<td>Accepts 27G blunt needle</td>
<td>Each</td>
</tr>
</tbody>
</table>
</div>