<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Primate Catheters &#8211; SAI Infusion Technologies</title>
	<atom:link href="https://www.sai-infusion.com/product-category/primate-catheters/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.sai-infusion.com</link>
	<description>Infusion and Sampling Products for Laboratory Animal Research</description>
	<lastBuildDate>Mon, 09 Feb 2026 20:32:06 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://www.sai-infusion.com/wp-content/uploads/2024/12/favicon_512-66x66.png</url>
	<title>Primate Catheters &#8211; SAI Infusion Technologies</title>
	<link>https://www.sai-infusion.com</link>
	<width>32</width>
	<height>32</height>
</image> 
<site xmlns="com-wordpress:feed-additions:1">244557463</site>	<item>
		<title>Primate Femoral Vein catheters</title>
		<link>https://www.sai-infusion.com/product/primate-femoral-vein-catheters-fvc-tapered/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Thu, 30 Jan 2025 16:06:23 +0000</pubDate>
				<guid isPermaLink="false">https://project2.digitalendeavordev.com/?post_type=product&#038;p=5530</guid>

					<description><![CDATA[Primate Tapered Femoral Vein Catheters gradually increase in size from tip to end, making for a seamless catheter that is small at the insertion point, but large and robust where you need it. Fine a complete list of our primate catheters, including our regular Primate Femoral Vein Catheter. Made of polyurethane, reducing blood platelet and  [...]]]></description>
										<content:encoded><![CDATA[<p>Primate Tapered Femoral Vein Catheters gradually increase in size from tip to end, making for a seamless catheter that is small at the insertion point, but large and robust where you need it. Fine a complete list of our primate catheters, including our regular Primate Femoral Vein Catheter.</p>
<ul>
<li>Made of polyurethane, reducing blood platelet and deposits on tubing walls</li>
<li>Small insertion tip will reduce thrombosis</li>
<li>Biocompatible</li>
</ul>
<div style="height: 20px; width: 100%;"></div>
<div class="table-2">
<table width="100%">
<thead>
<tr>
<th>Part #</th>
<th>Size</th>
<th>Suture Beads</th>
<th>Female Luer</th>
</tr>
</thead>
<tbody>
<tr>
<td>PTFVC-1</td>
<td>3-6 F</td>
<td>10 &amp; 11 cm</td>
<td>No</td>
</tr>
<tr>
<td>PTFVC-2</td>
<td>4-6 F</td>
<td>10 &amp; 11 cm</td>
<td>No</td>
</tr>
</tbody>
</table>
</div>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">5530</post-id>	</item>
		<item>
		<title>Primate Duodenal Catheter</title>
		<link>https://www.sai-infusion.com/product/primate-duodenal-catheter/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Thu, 30 Jan 2025 16:03:43 +0000</pubDate>
				<guid isPermaLink="false">https://project2.digitalendeavordev.com/?post_type=product&#038;p=5431</guid>

					<description><![CDATA[These catheters are designed for duodenal or gastric delivery in primates. The catheter is closed-ended, and has a slit-valve to prevent clogging. If you prefer beads instead of a patch, check out the Primate Duodenal Catheter. SAI also offers a complete line of primate catheters. If you need help determining which catheter is best for  [...]]]></description>
										<content:encoded><![CDATA[<p>These catheters are designed for duodenal or gastric delivery in primates. The catheter is closed-ended, and has a slit-valve to prevent clogging. If you prefer beads instead of a patch, check out the Primate Duodenal Catheter. SAI also offers a complete line of primate catheters. If you need help determining which catheter is best for your study, contact us and we will gladly assist you.</p>
<ul>
<li>Made from silicone: highly resistant to chemicals, and pliable to reduce vessel trauma</li>
<li>Suture patch provides reinforcement at the catheter insertion site</li>
<li>Available with or without a female luer</li>
<li>Listed lengths are 60cm with suture patch and one bead</li>
<li>Custom lengths and suture bead placement available, contact us with questions</li>
</ul>
<div style="height: 20px; width: 100%;"></div>
<div class="table-2">
<table width="100%">
<thead>
<tr>
<th>Part #</th>
<th>Size</th>
<th>Length</th>
<th>Suture Patch</th>
<th>Suture Beads</th>
<th>Female Luer</th>
</tr>
</thead>
<tbody>
<tr>
<td>PDC-1</td>
<td>3 F</td>
<td>60 cm</td>
<td>6 cm</td>
<td>8 cm</td>
<td>No</td>
</tr>
</tbody>
</table>
</div>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">5431</post-id>	</item>
		<item>
		<title>PE lined PU Intrathecal Catheter</title>
		<link>https://www.sai-infusion.com/product/dog-primate-sheep-lumbar-catheter/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Thu, 30 Jan 2025 15:55:20 +0000</pubDate>
				<guid isPermaLink="false">https://project2.digitalendeavordev.com/?post_type=product&#038;p=5226</guid>

					<description><![CDATA[Polyethylene (PE) lined polyurethane (PU) catheters provide researchers with the flexibility and biocompatibility of a PU exterior plus the chemical inertness of an interior coated with PE. Built in sheath for added stability and protection Perfect for dosing For intrathecal sampling, try our Cisterna Magna catheter Part # Description IT-PEPU-20 Polyethylene-lined polyurethane lumbar intrathecal catheter.  [...]]]></description>
										<content:encoded><![CDATA[<p>Polyethylene (PE) lined polyurethane (PU) catheters provide researchers with the flexibility and biocompatibility of a PU exterior plus the chemical inertness of an interior coated with PE.</p>
<ul>
<li>Built in sheath for added stability and protection</li>
<li>Perfect for dosing</li>
<li>For intrathecal sampling, try our Cisterna Magna catheter</li>
</ul>
<div style="height: 20px; width: 100%;"></div>
<div class="table-2">
<table width="100%">
<thead>
<tr>
<th>Part #</th>
<th>Description</th>
</tr>
</thead>
<tbody>
<tr>
<td>IT-PEPU-20</td>
<td>Polyethylene-lined polyurethane lumbar intrathecal catheter. 10 cm long IT portion<br />
with a 9 cm sheathed part for extra strength. Fits 6 F access port</td>
</tr>
<tr>
<td>IT-PEPU-35</td>
<td>Polyethylene-lined polyurethane lumbar intrathecal catheter. 10 cm long<br />
IT portion with a 24 cm sheathed part for extra strength. Fits 6 F access port</td>
</tr>
<tr>
<td>IT-PEPU-80</td>
<td>Polyethylene-lined polyurethane lumbar intrathecal catheter. 10 cm long<br />
IT portion with a 67 cm sheathed part for extra strength. Fits 6 F access port</td>
</tr>
</tbody>
</table>
</div>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">5226</post-id>	</item>
		<item>
		<title>CM Catheter with tapered bead</title>
		<link>https://www.sai-infusion.com/product/dog-primate-sheep-cisterna-magna-catheter/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Thu, 30 Jan 2025 15:50:47 +0000</pubDate>
				<guid isPermaLink="false">https://project2.digitalendeavordev.com/?post_type=product&#038;p=5021</guid>

					<description><![CDATA[Several options are available for CSF dosing and sampling studies and the option you need will be based on your study design. The CM catheter is typically preferred for serial sampling of cerebrospinal fluid. For infusion studies, we also offer the Lumbar Catheter. If you aren’t sure what works best for your study, contact us  [...]]]></description>
										<content:encoded><![CDATA[<p>Several options are available for CSF dosing and sampling studies and the option you need will be based on your study design. The CM catheter is typically preferred for serial sampling of cerebrospinal fluid. For infusion studies, we also offer the Lumbar Catheter. If you aren’t sure what works best for your study, contact us &#8211;  we’ll be happy to discuss the details and get you the items you need.</p>
<ul>
<li>Tapered catheter design for ease of insertion and catheter strength</li>
<li>Fenestrated tips for optimal CSF flow</li>
<li>Designs with either beads or patches for securing the catheter</li>
<li>Several vascular access ports options available for a variety of species catheter</li>
</ul>
<div style="height: 20px; width: 100%;"></div>
<div class="table-2">
<table width="100%">
<thead>
<tr>
<th>Part #</th>
<th>Description</th>
</tr>
</thead>
<tbody>
<tr>
<td>ITC-01</td>
<td>4-6 F tapered catheter with tapered bead for easy catheter insertion.<br />
Fenestrations at catheter tip for optimal CSF flow. Radio opaque polyurethane</td>
</tr>
<tr>
<td>CMC-01</td>
<td>3-4 F tapered catheter with suture bead for easy catheter insertion.<br />
Fenestrations at catheter tip for optimal CSF flow. Radio opaque polyurethane</td>
</tr>
<tr>
<td>CMC-02C</td>
<td>5 F polyurethane catheter with dural suture patch and fenestrations for optimal CSF flow.</td>
</tr>
<tr>
<td>CM-05</td>
<td>5-6 F tapered catheter with tapered bead for easy catheter insertion.<br />
Fenestrations at catheter tip for optimal CSF flow. Radio opaque polyurethane</td>
</tr>
</tbody>
</table>
</div>
]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">5021</post-id>	</item>
	</channel>
</rss>